When the output voltage and current of potentiostat reach the maximum, C1 potential indicator drops?
- Author:Libo
 - Source:wbeijingzhixunshejizhuangxiuwang.com
 - Date:2021-06-11
 - Click:0
 
Cause of failure: insulation flange short circuit; Or short circuit with other underground metal structures; Treatment method of reference electrode damage: repair short-circuit insulation flange, disconnect underground metal structure; Check the reference electrode measurement line or replace the reference electrode

 
 
 
 
 